Official ICT switch settings
XBA-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWT8US60800-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject $ 1 | ON | — | — | — | — | — | — | — |
| Accept $ 1factory default | OFF | — | — | — | — | — | — | — |
| Reject $ 5 | — | ON | — | — | — | — | — | — |
| Accept $ 5factory default | — | OFF | — | — | — | — | — | — |
| Reject $ 10 | — | — | ON | — | — | — | — | — |
| Accept $ 10factory default | — | — | OFF | — | — | — | — | — |
| Reject $ 20 | — | — | — | ON | — | — | — | — |
| Accept $ 20factory default | — | — | — | OFF | — | — | — | — |
| Reject $ 50 & 100 | — | — | — | — | ON | — | — | — |
| Accept $ 50 & 100factory default | — | — | — | — | OFF | — | — | — |
| Disable Bill Reject 4 Times / BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times / BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Inhibit Active HIGH | ON | — | — | — | — | — | — | — |
| Inhibit Active LOWfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Credit-Pulse Normal HIGH / Scaling Factor (SF) = 100, Decimal Place = 2 / Connect with coin changefactory default | — | — | — | — | ON | — | — | — |
| Credit-Pulse Normal LOW / Scaling Factor (SF) = 1, Decimal Place = 0 / Connect with ICT JPSTD Converter board | — | — | — | — | OFF | — | — | — |
| Pulse Modefactory default | — | — | — | — | — | ON | — | — |
| Other Mode | — | — | — | — | — | OFF | — | — |
| 1 pulse / USD 1 / MDB Modefactory default | — | — | — | — | — | — | OFF | OFF |
| 2 pulse / USD 1 / ICT002U Mode | — | — | — | — | — | — | OFF | ON |
| 4 pulse / USD 1 / ICT104U Mode | — | — | — | — | — | — | ON | OFF |
| 20 pulse / USD 1 / ICT104V Mode | — | — | — | — | — | — | ON | ON |
| Bill value | ICT002U | ICT104U | ICT104V | Pulse | MDB |
|---|---|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | USD 5 | USD 5 | USD 5 | USD 5 |
| BV3 | USD 10 | USD 10 | USD 10 | USD 10 | USD 5 |
| BV4 | USD 20 | USD 20 | USD 20 | USD 20 | USD 10 |
| BV5 | USD 50 | USD 50 | USD 50 | USD 50 | USD 20 |
| BV6 | USD 100 | USD 100 | USD 100 | USD 100 | USD 50 |
| BV7 | — | — | — | — | USD 100 |
Before you power up
- After setting the DIP switch of the credit pulses, reset the bill acceptor again.
- Calibration card is needed.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.