Official ICT switch settings
XBA-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWU5US60100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — |
| Reject USD 5 | — | ON | — | — | — | — | — | — |
| Accept USD 5factory default | — | OFF | — | — | — | — | — | — |
| Reject USD 10 | — | — | ON | — | — | — | — | — |
| Accept USD 10factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 20 | — | — | — | ON | — | — | — | — |
| Accept USD 20factory default | — | — | — | OFF | — | — | — | — |
| Reject USD 50 & 100 | — | — | — | — | ON | — | — | — |
| Accept USD 50 & 100factory default | — | — | — | — | OFF | — | — | — |
| Disable Bill Reject 4 Times — BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times — BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Inhibit Active HIGH | ON | — | — | — | — | — | — | — |
| Inhibit Active LOWfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Credit-Pulse Normal HIGH / Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2 / 9600 Baud Rate / Connect with coin changerfactory default | — | — | — | — | — | ON | — | — |
| Credit-Pulse Normal LOW / Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0 / 19200 Baud Rate / Connect with ICT JPSTD converter board | — | — | — | — | — | OFF | — | — |
| Pulse Modefactory default | — | — | — | — | — | — | ON | — |
| Other Mode | — | — | — | — | — | — | OFF | — |
| 1 pulse / USD 1 — MDB Modefactory default | — | — | — | — | — | — | OFF | OFF |
| 2 pulses / USD 1 — ICT106U Mode | — | — | — | — | — | — | OFF | ON |
| 5 pulses / USD 1 — ccNet Mode | — | — | — | — | — | — | ON | OFF |
| 20 pulses / USD 1 — ICT104V Mode | — | — | — | — | — | — | ON | ON |
| Bill value | Pulse | MDB | ICT104V | ccNet | ICT106U |
|---|---|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | — | USD 5 | USD 5 | USD 5 |
| BV3 | USD 10 | USD 5 | USD 10 | USD 10 | USD 10 |
| BV4 | USD 20 | USD 10 | USD 20 | USD 20 | USD 20 |
| BV5 | USD 50 | USD 20 | USD 50 | USD 50 | USD 50 |
| BV6 | USD 100 | USD 50 | USD 100 | USD 100 | USD 100 |
| BV7 | — | USD 100 | — | — | — |
Before you power up
- (1) After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- (2) Calibration card is needed.