Official ICT switch settings
XBA-UCD7(USD4+CAD3) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWT8UC720-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 & USD / CAD 5 | ON | — | — | — | — | — | — | — |
| Accept USD 1 & USD / CAD 5factory default | OFF | — | — | — | — | — | — | — |
| Reject USD / CAD 10 | — | ON | — | — | — | — | — | — |
| Accept USD / CAD 10factory default | — | OFF | — | — | — | — | — | — |
| Reject USD / CAD 20 | — | — | ON | — | — | — | — | — |
| Accept USD / CAD 20factory default | — | — | OFF | — | — | — | — | — |
| Accept USD+CADfactory default | — | — | — | OFF | OFF | — | — | — |
| Accept USD | — | — | — | OFF | ON | — | — | — |
| Accept CAD | — | — | — | ON | OFF | — | — | — |
| Reserved | — | — | — | ON | ON | — | — | — |
| Disable Bill Reject 4 Times BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
- This dip switch is located at the side of XBA.
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Inhibit Active HIGH | ON | — | — | — |
| Inhibit Active LOWfactory default | OFF | — | — | — |
| Colorful light | — | OFF | OFF | — |
| The green light flashesfactory default | — | OFF | ON | — |
| Reserved | — | ON | OFF | — |
| No light | — | ON | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 |
|---|---|
| Credit-Pulse Normal HIGHfactory default | ON |
| Credit-Pulse Normal LOW | OFF |
| Pulse Modefactory default | ON |
| Other Mode | OFF |
| Function | SW2 |
|---|---|
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory default | ON |
| Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0 | OFF |
| Connect with coin changerfactory default | ON |
| Connect with ICT JPSTD Converter board | OFF |
| Function | SW1 | SW2 |
|---|---|---|
| 1 pulse / USD&CAD 1 / MDB Modefactory default | OFF | OFF |
| 2 pulses / USD&CAD 1 / ICT002U Mode | OFF | ON |
| 4 pulses / USD&CAD 1 / ICT104U Mode | ON | OFF |
| 20 pulses / USD&CAD 1 / ICT104V Mode | ON | ON |
| Bill value | ICT002U | ICT104U | ICT104V | Pulse | MDB |
|---|---|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | USD 5 | USD 5 | USD 5 | USD 5 |
| BV3 | USD 10 | USD 10 | USD 10 | USD 10 | USD 10 |
| BV4 | USD 20 | USD 20 | USD 20 | USD 20 | USD 20 |
| BV5 | CAD 5 | CAD 5 | CAD 5 | CAD 5 | CAD 5 |
| BV6 | CAD 10 | CAD 10 | CAD 10 | CAD 10 | CAD 10 |
| BV7 | CAD 20 | CAD 20 | CAD 20 | CAD 20 | CAD 20 |
Before you power up
- This dip switch is located at the side of XBA.
- This dip switch is located on the CPU board, remove the CPU board cover first.
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- Note: 1. Calibration card is needed.
- 2. 1 USD = 1 CAD.