Official ICT switch settings

XBA-UCD7(USD4+CAD3) DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWT8UC720-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

XBA-UCD7 Option Switch Settings: primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1 & USD / CAD 5ON
Accept USD 1 & USD / CAD 5factory defaultOFF
Reject USD / CAD 10ON
Accept USD / CAD 10factory defaultOFF
Reject USD / CAD 20ON
Accept USD / CAD 20factory defaultOFF
Accept USD+CADfactory defaultOFFOFF
Accept USDOFFON
Accept CADONOFF
ReservedONON
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Stack Banknote when Power-upON
Reject Banknote when Power-upfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
  • This dip switch is located at the side of XBA.
XBA-UCD7 (Pulse/MDB/ICT): upper interface settings
FunctionSW1SW2SW3SW4
Inhibit Active HIGHON
Inhibit Active LOWfactory defaultOFF
Colorful lightOFFOFF
The green light flashesfactory defaultOFFON
ReservedONOFF
No lightONON
ReservedON
Reservedfactory defaultOFF
XBA-UCD7 (Pulse/MDB/ICT): Pulse Mode selection
FunctionSW1
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
Other ModeOFF
XBA-UCD7 (Pulse/MDB/ICT): MDB / ICT104V option settings
FunctionSW2
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Connect with coin changerfactory defaultON
Connect with ICT JPSTD Converter boardOFF
XBA-UCD7 (Pulse/MDB/ICT): mode and pulse-count selection
FunctionSW1SW2
1 pulse / USD&CAD 1 / MDB Modefactory defaultOFFOFF
2 pulses / USD&CAD 1 / ICT002U ModeOFFON
4 pulses / USD&CAD 1 / ICT104U ModeONOFF
20 pulses / USD&CAD 1 / ICT104V ModeONON
Currency Assign Data
Bill valueICT002UICT104UICT104VPulseMDB
BV1USD 1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5USD 5USD 5
BV3USD 10USD 10USD 10USD 10USD 10
BV4USD 20USD 20USD 20USD 20USD 20
BV5CAD 5CAD 5CAD 5CAD 5CAD 5
BV6CAD 10CAD 10CAD 10CAD 10CAD 10
BV7CAD 20CAD 20CAD 20CAD 20CAD 20
Before you power up
  • This dip switch is located at the side of XBA.
  • This dip switch is located on the CPU board, remove the CPU board cover first.
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: 1. Calibration card is needed.
  • 2. 1 USD = 1 CAD.