Official ICT switch settings

XBA mini-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWX2US62001-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

XBA mini Option Switch Settings: 1 (Pulse/MDB/JPSTD/ICT104U/ICT104V) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
Disable Bill Reject 4 Times / BA Stop By 30 SecON
Enable Bill Reject 4 Times / BA Stop By 30 Secfactory defaultOFF
Colorful lightOFFOFF
The green light flashesfactory defaultOFFON
ReservedONOFF
No lightONON
XBA mini Option Switch Settings: 1 (Pulse/MDB/JPSTD/ICT104U/ICT104V) — 4-switch setting
FunctionSW1SW2SW3SW4
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Interface Timing Conversion: 5ms LO / 5ms HIfactory defaultOFFOFF
Interface Timing Conversion: 5ms LO / 10ms HIONOFF
Interface Timing Conversion: 10ms LO / 10ms HIOFFON
Interface Timing Conversion: 20ms LO / 20ms HIONON
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
Other ModeOFF
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1OFFON
4 pulses / USD 1ONOFF
20 pulses / USD 1ONON
Interface Settings: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeON
Other Modefactory defaultOFF
MDB ModeOFFOFF
JPSTD ModeOFFON
ICT104U Modefactory defaultONOFF
ICT104V ModeONON
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Connect with coin changerfactory defaultON
Connect with ICT VCCS Converter boardOFF
Pulse ModeON
Other Modefactory defaultOFF
MDB ModeOFFOFF
JPSTD ModeOFFON
ICT104U ModeONOFF
ICT104V Modefactory defaultONON
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeON
Other Modefactory defaultOFF
MDB Modefactory defaultOFFOFF
JPSTD ModeOFFON
ICT104U ModeONOFF
ICT104V ModeONON
Currency Assign Data
Bill valueICT104UICT104VJPSTDPulseMDB
BV111111
BV25
BV31010105
BV420202010
BV550505020
BV610010010050
BV7100
Before you power up
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Calibration card is needed.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp