Official ICT switch settings
XBA mini-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWX2US60301-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 (8-switch DIP) | SW2 (8-switch DIP) | SW3 (8-switch DIP) | SW4 (8-switch DIP) | SW5 (8-switch DIP) | SW6 (8-switch DIP) | SW7 (8-switch DIP) | SW8 (8-switch DIP) | SW1 (4-switch DIP) | SW2 (4-switch DIP) | SW3 (4-switch DIP) | SW4 (4-switch DIP) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — | — | — | — | — |
| Reject USD 5 | — | ON | — | — | — | — | — | — | — | — | — | — |
| Accept USD 5factory default | — | OFF | — | — | — | — | — | — | — | — | — | — |
| Reject USD 10 | — | — | ON | — | — | — | — | — | — | — | — | — |
| Accept USD 10factory default | — | — | OFF | — | — | — | — | — | — | — | — | — |
| Reject USD 20 | — | — | — | ON | — | — | — | — | — | — | — | — |
| Accept USD 20factory default | — | — | — | OFF | — | — | — | — | — | — | — | — |
| Reject USD 50 & 100 | — | — | — | — | ON | — | — | — | — | — | — | — |
| Accept USD 50 & 100factory default | — | — | — | — | OFF | — | — | — | — | — | — | — |
| Disable Bill Reject 4 Times / BA Stop By 30 Sec | — | — | — | — | — | ON | — | — | — | — | — | — |
| Enable Bill Reject 4 Times / BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — | — | — | — | — |
| Colorful light | — | — | — | — | — | — | OFF | OFF | — | — | — | — |
| The green light flashesfactory default | — | — | — | — | — | — | OFF | ON | — | — | — | — |
| Reserved | — | — | — | — | — | — | ON | OFF | — | — | — | — |
| No light | — | — | — | — | — | — | ON | ON | — | — | — | — |
| Inhibit Active High | — | — | — | — | — | — | — | — | ON | — | — | — |
| Inhibit Active Lowfactory default | — | — | — | — | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | — | — | — | — | OFF | — | — |
| Interface Timing Conversion (5ms LO / 5ms HI)factory default | — | — | — | — | — | — | — | — | — | — | OFF | OFF |
| Interface Timing Conversion (5ms LO / 10ms HI) | — | — | — | — | — | — | — | — | — | — | ON | OFF |
| Interface Timing Conversion (10ms LO / 10ms HI) | — | — | — | — | — | — | — | — | — | — | OFF | ON |
| Interface Timing Conversion (20ms LO / 20ms HI) | — | — | — | — | — | — | — | — | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | — | — |
| Other Mode | — | OFF | — | — |
| 1 pulse / USD 1factory default | — | — | OFF | OFF |
| 2 pulses / USD 1 | — | — | OFF | ON |
| 4 pulses / USD 1 | — | — | ON | OFF |
| 20 pulses / USD 1 | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reservedfactory default | ON | — | — | — |
| Reserved | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| Other Modefactory default | — | OFF | — | — |
| MDB Mode | — | — | OFF | OFF |
| JPSTD Mode | — | — | OFF | ON |
| ICT104U Modefactory default | — | — | ON | OFF |
| ICT104V Mode | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Connect with coin changerfactory default | ON | — | — | — |
| Connect with ICT JPSTD Converter board | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| Other Modefactory default | — | OFF | — | — |
| MDB Mode | — | — | OFF | OFF |
| JPSTD Mode | — | — | OFF | ON |
| ICT104U Mode | — | — | ON | OFF |
| ICT104V Modefactory default | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100 / Decimal Point Position (DPP) = 2factory default | ON | — | — | — |
| Scaling Factor (SF) = 1 / Decimal Point Position (DPP) = 0 | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| Other Modefactory default | — | OFF | — | — |
| MDB Modefactory default | — | — | OFF | OFF |
| JPSTD Mode | — | — | OFF | ON |
| ICT104U Mode | — | — | ON | OFF |
| ICT104V Mode | — | — | ON | ON |
| Bill value | ICT104U | ICT104V | JPSTD | Pulse | MDB |
|---|---|---|---|---|---|
| BV1 | 1 | 1 | 1 | 1 | 1 |
| BV2 | 5 | 5 | — | 5 | — |
| BV3 | 10 | 10 | — | 10 | 5 |
| BV4 | 20 | 20 | — | 20 | 10 |
| BV5 | 50 | 50 | — | 50 | 20 |
| BV6 | 100 | 100 | — | 100 | 50 |
| BV7 | — | — | — | — | 100 |
Before you power up