Official ICT switch settings
XBA mini-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWBPUS63000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — |
| Reject USD 5 | — | ON | — | — | — | — | — | — |
| Accept USD 5factory default | — | OFF | — | — | — | — | — | — |
| Reject USD 10 | — | — | ON | — | — | — | — | — |
| Accept USD 10factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 20 | — | — | — | ON | — | — | — | — |
| Accept USD 20factory default | — | — | — | OFF | — | — | — | — |
| Reject USD 50 & 100 | — | — | — | — | ON | — | — | — |
| Accept USD 50 & 100factory default | — | — | — | — | OFF | — | — | — |
| Disable Bill Reject 4 Times BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Colorful light | — | — | — | — | — | — | OFF | OFF |
| The green light flashesfactory default | — | — | — | — | — | — | OFF | ON |
| Reserved | — | — | — | — | — | — | ON | OFF |
| No light | — | — | — | — | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Inhibit Active High | ON | — | — | — |
| Inhibit Active Lowfactory default | OFF | — | — | — |
| Reserved | — | ON | — | — |
| Reservedfactory default | — | OFF | — | — |
| Interface Timing Conversion: 50ms LO / 50ms HIfactory default | — | — | OFF | OFF |
| Interface Timing Conversion: 60ms LO / 300ms HI | — | — | ON | OFF |
| Interface Timing Conversion: 30ms LO / 50ms HI | — | — | OFF | ON |
| Interface Timing Conversion: 150ms LO / 150ms HI | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | — | — |
| Other Mode | — | OFF | — | — |
| 1 pulse / USD 1factory default | — | — | OFF | OFF |
| 2 pulses / USD 1 | — | — | OFF | ON |
| 4 pulses / USD 1 | — | — | ON | OFF |
| 20 pulses / USD 1 | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| Other Modefactory default | — | OFF | — | — |
| Reserved | — | — | OFF | OFF |
| Reserved | — | — | OFF | ON |
| ICT-BC Modefactory default | — | — | ON | OFF |
| Reserved | — | — | ON | ON |
| Bill value | Pulse | ICT-BC |
|---|---|---|
| BV1 | 1 | 1 |
| BV2 | 5 | 5 |
| BV3 | 10 | 10 |
| BV4 | 20 | 20 |
| BV5 | 50 | 50 |
| BV6 | 100 | 100 |
Before you power up
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- Calibration card is needed.
- ICT BC Protocol supports USB and RS-232.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.
