Official ICT switch settings
XBA mini-UMR12(USD6+MYR6) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWFCUMC0100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 & 5 & 10 | ON | — | — | — | — | — | — | — |
| Accept USD 1 & 5 & 10factory default | OFF | — | — | — | — | — | — | — |
| Reject USD 20 & 50 | — | ON | — | — | — | — | — | — |
| Accept USD 20 & 50factory default | — | OFF | — | — | — | — | — | — |
| Reject USD 100 | — | — | ON | — | — | — | — | — |
| Accept USD 100factory default | — | — | OFF | — | — | — | — | — |
| Reject MYR 1 & 5 & 10 | — | — | — | ON | — | — | — | — |
| Accept MYR 1 & 5 & 10factory default | — | — | — | OFF | — | — | — | — |
| Reject MYR 20 & 50 & 100 | — | — | — | — | ON | — | — | — |
| Accept MYR 20 & 50 & 100factory default | — | — | — | — | OFF | — | — | — |
| Disable Bill Reject 4 Times — BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times — BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Inhibit Active High | ON | — | — | — |
| Inhibit Active Lowfactory default | OFF | — | — | — |
| Reserved | — | ON | — | — |
| Reservedfactory default | — | OFF | — | — |
| Interface Timing Conversion — 50ms LO / 50ms HIfactory default | — | — | OFF | OFF |
| Interface Timing Conversion — 60ms LO / 300ms HI | — | — | ON | OFF |
| Interface Timing Conversion — 30ms LO / 50ms HI | — | — | OFF | ON |
| Interface Timing Conversion — 150ms LO / 150ms HI | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | — | — |
| ICT104U Mode | — | OFF | — | — |
| 1 pulse / MYR 1factory default | — | — | OFF | OFF |
| 2 pulses / MYR 1 | — | — | OFF | ON |
| 5 pulses / MYR 1 | — | — | ON | OFF |
| 10 pulses / MYR 1 | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| ICT104U Modefactory default | — | OFF | — | — |
| Reserved | — | — | ON | — |
| Reservedfactory default | — | — | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Bill value | Pulse | ICT104U |
|---|---|---|
| BV1 | MYR 1 | MYR 1 |
| BV2 | MYR 5 | MYR 5 |
| BV3 | MYR 10 | MYR 10 |
| BV4 | MYR 20 | MYR 20 |
| BV5 | MYR 50 | MYR 50 |
| BV6 | MYR 100 | MYR 100 |
| BV7 | USD 1 | USD 1 |
| BV8 | USD 5 | USD 5 |
| BV9 | USD 10 | USD 10 |
| BV10 | USD 20 | USD 20 |
| BV11 | USD 50 | USD 50 |
| BV12 | USD 100 | USD 100 |
Before you power up
- 1. After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- 2. Calibration card is needed.
- 3. Pulse Mode: USD 1 = MYR 5.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.
