XBA mini Option Switch Settings: 1: primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject MXN 20 & USD 1ON
Accept MXN 20 & USD 1factory defaultOFF
Reject MXN 50 & USD 5ON
Accept MXN 50 & USD 5factory defaultOFF
Reject MXN 100 & USD 10ON
Accept MXN 100 & USD 10factory defaultOFF
Reject MXN 200 & USD 20ON
Accept MXN 200 & USD 20factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Stack Banknote when Power-upON
Reject Banknote when Power-upfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: (1) Calibration card is needed.
  • (2) Exchange Rate on USD to MXN is 1:10.
XBA mini Option Switch Settings: 1: auxiliary settings
FunctionSW1SW2SW3SW4
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
Other ModeOFF
1 pulse / MXN 10factory defaultOFFOFF
2 pulses / MXN 10OFFON
5 pulses / MXN 10ONOFF
10 pulses / MXN 10ONON
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Connect with coin changerON
Connect with ICT JPSTD converter boardfactory defaultOFF
Pulse ModeON
Other Modefactory defaultOFF
MDB ModeOFFOFF
JPSTD ModeOFFON
ICT104U ModeONOFF
ICT104V Modefactory defaultONON
Interface Settings: 2 (Other)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeON
Other Modefactory defaultOFF
MDB ModeOFFOFF
JPSTD ModeOFFON
ICT104U ModeONOFF
ICT104V Modefactory defaultONON
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeON
Other Modefactory defaultOFF
MDB Modefactory defaultOFFOFF
JPSTD ModeOFFON
ICT104U ModeONOFF
ICT104V ModeONON
Currency Assign Data
Bill valueJPSTDICT104UICT104VPulseMDB
BV1USD 1USD 1USD 1USD 1USD 1
BV2MXN 20MXN 20MXN 20MXN 20MXN 20
BV3MXN 50 & USD 5MXN 50 & USD 5MXN 50 & USD 5MXN 50 & USD 5MXN 50 & USD 5
BV4MXN 100 & USD 10MXN 100 & USD 10MXN 100 & USD 10MXN 100 & USD 10MXN 100 & USD 10
BV5MXN 200 & USD 20MXN 200 & USD 20MXN 200 & USD 20MXN 200 & USD 20MXN 200 & USD 20
Before you power up
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: (1) Calibration card is needed.
  • (2) Exchange Rate on USD to MXN is 1:10.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.