Every switch function from ICT’s own setting sheet (part number SWZ483X10-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| BA disable 30 sec. / After reject bill 4 times consecutively | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times / BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| ENABLE IrDA Download | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
- This dip switch is located at the side of XBA.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| ICT108U | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
- This dip switch is located on the CPU board; remove the CPU board cover first.
| Bill value | ICT108U (CHF) | ICT108U (CNY) | ICT108U (EUR) | ICT108U (GBP) | ICT108U (JPY) | ICT108U (RUB) | ICT108U (TRY) | ICT108U (USD) |
|---|---|---|---|---|---|---|---|---|
| BV1 | CHF 10 | — | — | — | — | — | — | — |
| BV2 | CHF 20 | — | — | — | — | — | — | — |
| BV3 | CHF 50 | — | — | — | — | — | — | — |
| BV4 | CHF 100 | — | — | — | — | — | — | — |
| BV5 | — | CNY 1 | — | — | — | — | — | — |
| BV6 | — | CNY 5 | — | — | — | — | — | — |
| BV7 | — | CNY 10 | — | — | — | — | — | — |
| BV8 | — | CNY 20 | — | — | — | — | — | — |
| BV9 | — | CNY 50 | — | — | — | — | — | — |
| BV10 | — | CNY 100 | — | — | — | — | — | — |
| BV11 | — | — | EUR 5 | — | — | — | — | — |
| BV12 | — | — | EUR 10 | — | — | — | — | — |
| BV13 | — | — | EUR 20 | — | — | — | — | — |
| BV14 | — | — | EUR 50 | — | — | — | — | — |
| BV15 | — | — | — | GBP 5 | — | — | — | — |
| BV16 | — | — | — | GBP 10 | — | — | — | — |
| BV17 | — | — | — | — | JPY 1000 | — | — | — |
| BV18 | — | — | — | — | JPY 2000 | — | — | — |
| BV19 | — | — | — | — | JPY 5000 | — | — | — |
| BV20 | — | — | — | — | JPY 10000 | — | — | — |
| BV21 | — | — | — | — | — | RUB 10 | — | — |
| BV22 | — | — | — | — | — | RUB 50 | — | — |
| BV23 | — | — | — | — | — | RUB 100 | — | — |
| BV24 | — | — | — | — | — | RUB 500 | — | — |
| BV25 | — | — | — | — | — | RUB 1000 | — | — |
| BV26 | — | — | — | — | — | — | TRY 5 | — |
| BV27 | — | — | — | — | — | — | TRY 10 | — |
| BV28 | — | — | — | — | — | — | TRY 20 | — |
| BV29 | — | — | — | — | — | — | TRY 50 | — |
| BV30 | — | — | — | — | — | — | TRY 100 | — |
| BV31 | — | — | — | — | — | — | TRY 200 | — |
| BV32 | — | — | — | — | — | — | — | USD 1 |
| BV33 | — | — | — | — | — | — | — | USD 5 |
| BV34 | — | — | — | — | — | — | — | USD 10 |
| BV35 | — | — | — | — | — | — | — | USD 20 |
| BV36 | — | — | — | — | — | — | — | USD 50 |
| BV37 | — | — | — | — | — | — | — | USD 100 |
Before you power up
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- No sleep function.