Official ICT switch settings
XBA-82X DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWZ482X10-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| BA disable 30 sec. / After reject bill 4 times consecutively | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times / BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| ENABLE IrDA Download | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| ICT108Ufactory default | — | — | — | — | — | — | ON | — |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Bill value | ICT108U |
|---|---|
| BV1 | AUD 5 |
| BV2 | AUD 10 |
| BV3 | AUD 20 |
| BV4 | AUD 50 |
| BV5 | AUD 100 |
| BV6 | CNY 1 |
| BV7 | CNY 5 |
| BV8 | CNY 10 |
| BV9 | CNY 20 |
| BV10 | CNY 50 |
| BV11 | CNY 100 |
| BV12 | EUR 5 |
| BV13 | EUR 10 |
| BV14 | EUR 20 |
| BV15 | EUR 50 |
| BV16 | GBP 5 |
| BV17 | GBP 10 |
| BV18 | JPY 1000 |
| BV19 | JPY 2000 |
| BV20 | JPY 5000 |
| BV21 | JPY 10000 |
| BV22 | RUB 10 |
| BV23 | RUB 50 |
| BV24 | RUB 100 |
| BV25 | RUB 500 |
| BV26 | RUB 1000 |
| BV27 | SGD 2 |
| BV28 | SGD 5 |
| BV29 | SGD 10 |
| BV30 | SGD 50 |
| BV31 | USD 1 |
| BV32 | USD 5 |
| BV33 | USD 10 |
| BV34 | USD 20 |
| BV35 | USD 50 |
| BV36 | USD 100 |
Before you power up
- Affer setting dip switch of the credit pulses, you should reset the bill acceptor again.
- No sleep function.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.