Official ICT switch settings
XBA-41X DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWZ441X10-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Disable Bill Reject 4 Times — BA Stop By 30 Sec | — | — | — | — | — | ON | — | — |
| Enable Bill Reject 4 Times — BA Stop By 30 Secfactory default | — | — | — | — | — | OFF | — | — |
| Stack Banknote when Power-up | — | — | — | — | — | — | ON | — |
| Reject Banknote when Power-upfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reserved | ON | — | — | — | — | — | — | — |
| Reservedfactory default | OFF | — | — | — | — | — | — | — |
| Reserved | — | ON | — | — | — | — | — | — |
| Reservedfactory default | — | OFF | — | — | — | — | — | — |
| Reserved | — | — | ON | — | — | — | — | — |
| Reservedfactory default | — | — | OFF | — | — | — | — | — |
| Reserved | — | — | — | ON | — | — | — | — |
| Reservedfactory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| ICT108Ufactory default | — | — | — | — | — | — | ON | — |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
| Bill value | ICT108U |
|---|---|
| BV1 | INR 5 |
| BV2 | INR 10 |
| BV3 | INR 20 |
| BV4 | INR 50 |
| BV5 | INR 100 |
| BV6 | INR 200 |
| BV7 | INR 500 |
| BV8 | USD 1 |
| BV9 | USD 5 |
| BV10 | USD 10 |
| BV11 | USD 20 |
| BV12 | USD 50 |
| BV13 | USD 100 |
| BV14 | EUR 5 |
| BV15 | EUR 10 |
| BV16 | EUR 20 |
| BV17 | EUR 50 |
| BV18 | EUR 100 |
| BV19 | EUR 200 |
| BV20 | GBP 5 |
| BV21 | GBP 10 |
| BV22 | GBP 20 |
Before you power up
- This dip switch is located at the side of XBA.
- No sleep function.
- Calibrate card.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.