Official ICT switch settings

V7P-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWBVUS610-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7P Option Switch Settings: 1: primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
V7P Option Switch Settings: 1: pulse and timing settings
FunctionSW1SW2SW3SW4
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1ONOFF
4 pulses / USD 1OFFON
20 pulses / USD 1ONON
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT104U ModeOFFOFF
ICT104V ModeOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104U)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeONOFF
ICT104U Modefactory defaultOFFOFF
ICT104V ModeOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeONOFF
ICT104U ModeOFFOFF
ICT104V Modefactory defaultOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT104U ModeOFFOFF
ICT104V ModeOFFON
MDB Modefactory defaultONON
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT104UICT104VPulseMDB
BV1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5
BV3USD 10USD 10USD 10USD 5
BV4USD 20USD 20USD 20USD 10
BV5USD 50USD 50USD 50USD 20
BV6USD 100USD 100USD 100USD 50
BV7USD 100
Before you power up
  • (1) Default setting.
  • (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • (3) Remove the front cover and the dip-switch in on the CPU board.