Official ICT switch settings

V7P-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWE5US61000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7P Option Switch Settings: 1(Pulse/MDB/RS232 A0/ICT002U) — Switches 1–8
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
V7P Option Switch Settings: 1 — pulse denomination bank
FunctionSW1SW2
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1ONOFF
4 pulses / USD 1OFFON
20 pulses / USD 1ONON
V7P Option Switch Settings: 1 — interface timing bank
FunctionSW3SW4
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
Interface Settings: 2(Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT002U ModeOFFOFF
RS232 A0 ModeOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2(ICT002U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT002U Modefactory defaultOFFOFF
RS232 A0 ModeOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2(RS232 A0)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT002U ModeOFFOFF
RS232 A0 Modefactory defaultOFFON
MDB ModeONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2(MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT002U ModeOFFOFF
RS232 A0 ModeOFFON
MDB Modefactory defaultONON
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT002URS232 A0MDBPulse
BV1USD 1USD 1USD 1USD 1
BV2USD 5
BV3USD 10USD 5USD 5USD 10
BV4USD 20USD 10USD 10USD 20
BV5USD 50USD 20USD 20USD 50
BV6USD 100USD 50USD 50USD 100
BV7USD 100USD 100
Before you power up
  • Default setting.
  • Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • Remove the front cover and the dip-switch in on the CPU board.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.