Official ICT switch settings

V7P-UCD11 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWBVUCB0100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7P Option Switch Settings: 1 (Pulse / ICT104V / ICT104U / MDB)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW1-2SW2-2SW3-2SW4-2
Reject CAD 5 & 10 & 20ON
Accept CAD 5 & 10 & 20factory defaultOFF
Reject CAD 50 & 100ON
Accept CAD 50 & 100factory defaultOFF
Reject USD 1 & 5ON
Accept USD 1 & 5factory defaultOFF
Reject USD 10 & 20ON
Accept USD 10 & 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
1 pulse / CAD 1 & USD 1factory defaultOFFOFF
2 pulses / CAD 1 & USD 1ONOFF
4 pulses / CAD 1 & USD 1OFFON
20 pulses / CAD 1 & USD 1ONON
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
  • The internal switch block repeats the SW1–SW4 header; -2 disambiguates it in this JSON.
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT104V InterfaceOFFON
ICT104U InterfaceOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104V Interfacefactory defaultOFFON
ICT104U InterfaceOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104V InterfaceOFFON
ICT104U Interfacefactory defaultOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT104V InterfaceOFFON
ICT104U InterfaceOFFOFF
MDB Interfacefactory defaultONON
Reservedfactory defaultON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT104UICT104VMDBPulse
BV1CAD 5CAD 5CAD 5CAD 5
BV2CAD 10CAD 10CAD 10CAD 10
BV3CAD 20CAD 20CAD 20CAD 20
BV4CAD 50CAD 50CAD 50CAD 50
BV5CAD 100CAD 100CAD 100CAD 100
BV6USD 1USD 1USD 1USD 1
BV7USD 5USD 5USD 5USD 5
BV8USD 10USD 10USD 10USD 10
BV9USD 20USD 20USD 20USD 20
BV10USD 50USD 50USD 50USD 50
BV11USD 100USD 100USD 100USD 100
Before you power up
  • Dip Switch 1 is for Pulse.
  • Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • Remove the front cover and the dip-switch on the CPU board.
  • 1 USD = 1 CAD.