Official ICT switch settings

V7E/LX7-XCD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWR6XC60100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104V/ICT104U/MDB) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject XCD 5 & USD 1ON
Accept XCD 5 & USD 1factory defaultOFF
Reject XCD 10 & USD 5ON
Accept XCD 10 & USD 5factory defaultOFF
Reject XCD 20 & USD 10ON
Accept XCD 20 & USD 10factory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Pulse Mode / Other Mode
Harness Disable — BA stopped working when fishingON
Harness Enable — Normalfactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
  • Dip Switch 1 to 5 are only for Pulse mode.
  • Pulse working with $1 USD = $2 XCD.
  • MDB working with $1 USD = $2.5 XCD.
V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104V/ICT104U/MDB) — 4-switch pulse setting
FunctionSW1SW2SW3SW4
1 pulse / XCD 1factory defaultOFFOFF
5 pulses / XCD 1ONOFF
10 pulses / XCD 1OFFON
25 pulses / XCD 1ONON
Pulse Speed: 50ms LO / 50ms HIfactory defaultOFFOFF
Pulse Speed: 60ms LO / 300ms HIONOFF
Pulse Speed: 30ms LO / 50ms HIOFFON
Pulse Speed: 150ms LO / 150ms HIONON
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT104U InterfaceOFFOFF
ICT104V InterfaceOFFON
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104U Interfacefactory defaultOFFOFF
ICT104V InterfaceOFFON
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104U InterfaceOFFOFF
ICT104V Interfacefactory defaultOFFON
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 1OFF
Pulse ModeONOFF
ICT104U InterfaceOFFOFF
ICT104V InterfaceOFFON
MDB Interfacefactory defaultONON
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT104VICT104UPulseMDB
BV1XCD 5XCD 5XCD 5XCD 5
BV2XCD 10XCD 10XCD 10XCD 10
BV3XCD 20XCD 20XCD 20XCD 20
BV4USD 1USD 1USD 1USD 1
BV5USD 5USD 5USD 5USD 5
BV6USD 10USD 10USD 10USD 10
Before you power up
  • Please reset the bill acceptor after any changes on Dip switch.