V7E/LX7-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWP5US60600-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7E/LX7 dip-switch settings and functions (8-switch DIP)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness Disable (Other Mode: BA stops working when fishing)ON
Harness Enable (Other Mode: Normal)factory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
V7E/LX7 dip-switch settings and functions (4-switch DIP)
FunctionSW1SW2SW3SW4
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1ONOFF
4 pulses / USD 1OFFON
20 pulses / USD 1ONON
Pulse Speed: 50ms LO / 50ms HIfactory defaultOFFOFF
Pulse Speed: 60ms LO / 300ms HIONOFF
Pulse Speed: 30ms LO / 50ms HIOFFON
Pulse Speed: 150ms LO / 150ms HIONON
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Pulse Normal Highfactory defaultON
Pulse Normal LowOFF
Pulse Modefactory defaultONOFF
ICT002U InterfaceOFFON
MDB InterfaceONON
RS232 A0 ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (ICT002U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT002U Interfacefactory defaultOFFON
MDB InterfaceONON
RS232 A0 ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT002U InterfaceOFFON
MDB Interfacefactory defaultONON
RS232 A0 ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
DIP SWITCHES SETTING: 2 (RS232 A0)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT002U InterfaceOFFON
MDB InterfaceONON
RS232 A0 Modefactory defaultOFFOFF
ReservedON
Reservedfactory defaultOFF
RS232 A0 INFORMATION: BillType Data
Function
Code 1: USD 1
Code 2: Reserved
Code 3: USD 5
Code 4: USD 10
Code 5: USD 20
Code 6: USD 50
Code 7: USD 100
Currency Assign Data
Bill valuePulseRS232 A0ICT002UMDB
BV1USD 1USD 1USD 1USD 1
BV2USD 5USD 5
BV3USD 10USD 5USD 10USD 5
BV4USD 20USD 10USD 20USD 10
BV5USD 50USD 20USD 50USD 20
BV6USD 100USD 50USD 100USD 50
BV7USD 100USD 100
Before you power up
  • Default setting.
  • Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • Remove the front cover and the dip-switch in on the CPU board. (Please refer to “SW1” setting.)