Official ICT switch settings

V7E/LX7-BUD6(BBD4+USD2) DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWVR6BU62000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104U/MDB) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject BBD 2ON
Accept BBD 2factory defaultOFF
Reject BBD 5ON
Accept BBD 5factory defaultOFF
Reject BBD 10ON
Accept BBD 10factory defaultOFF
Reject BBD 20ON
Accept BBD 20factory defaultOFF
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Harness Disable (Other Mode: BA stops working when fishing)ON
Harness Enable (Other Mode: Normal)factory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
V7E/LX7 Option Switch Settings: 1 — 4-switch DIP (pulse protocol)
FunctionSW1SW2SW3SW4
1 pulse / BBD 1factory defaultOFFOFF
2 pulses / BBD 1ONOFF
4 pulses / BBD 1OFFON
20 pulses / BBD 1ONON
Pulse Speed — 50ms LO / 50ms HIfactory defaultOFFOFF
Pulse Speed — 60ms LO / 300ms HIONOFF
Pulse Speed — 30ms LO / 50ms HIOFFON
Pulse Speed — 150ms LO / 150ms HIONON
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Pulse Normal Highfactory defaultON
Pulse Normal LowOFF
Pulse Modefactory defaultONOFF
ICT104U InterfaceOFFON
MDB InterfaceONON
ReservedOFFOFF
Accept BBD polymerON
Accept BBD ALL (Paper & polymer)factory defaultOFF
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse Modefactory defaultONOFF
ICT104U InterfaceOFFON
MDB InterfaceONON
ReservedOFFOFF
Accept BBD polymerON
Accept BBD ALL (Paper & polymer)factory defaultOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT104U InterfaceOFFON
MDB Interfacefactory defaultONON
ReservedOFFOFF
Accept BBD polymerON
Accept BBD ALL (Paper & polymer)factory defaultOFF
Currency Assign Data
Bill valueICT104UPulseMDB
BV1BBD 2BBD 2BBD 2
BV2BBD 5BBD 5BBD 5
BV3BBD 10BBD 10BBD 10
BV4BBD 20BBD 20BBD 20
BV5USD 1USD 1USD 1
BV6USD 5USD 5USD 5
Before you power up
  • (1) Default setting.
  • (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • (3) Remove the front cover and the dip-switch in on the CPU board.
  • (4) Exchange rate: 1 USD = 2 BBD

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.