Official ICT switch settings

V7E/LX7-ANG8(ANG2+AWG2+USD4) DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWK4AN810-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

V7E/LX7 Option Switch Settings: 1 (MDB): primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject ANG 10 & AWG 10ON
Accept ANG 10 & AWG 10factory defaultOFF
Reject ANG 25 & AWG 25ON
Accept ANG 25 & AWG 25factory defaultOFF
Reject USD 1 & 5ON
Accept USD 1 & 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Exchange rate 1 USD=1.75 AWG/ANGON
Exchange rate 1 USD=1.00 AWG/ANGfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
  • Reset the bill acceptor after setting the dip switch.
V7E/LX7 Option Switch Settings: 1 (MDB): auxiliary settings 1
FunctionSW1SW2
Reservedfactory defaultOFFOFF
ReservedONOFF
ReservedOFFON
ReservedONON
V7E/LX7 Option Switch Settings: 1 (MDB): auxiliary settings 2
FunctionSW3SW4
Reservedfactory defaultOFFOFF
ReservedONOFF
ReservedOFFON
ReservedONON
DIP SWITCHES SETTING : 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2OFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
  • Remove the front cover and the dip-switch in on the CPU board.
Currency Assign Data
Bill valueMDB
BV1ANG 10 & AWG 10
BV2ANG 25 & AWG 25
BV3USD 1
BV4USD 5
BV5USD 10
BV6USD 20
Before you power up
  • Reset the bill acceptor after setting the dip switch.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp