Official ICT switch settings
V7-USD4 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWT3US40100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — |
| Reject USD 5 | — | ON | — | — | — | — | — | — |
| Accept USD 5factory default | — | OFF | — | — | — | — | — | — |
| Reject USD 10 | — | — | ON | — | — | — | — | — |
| Accept USD 10factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 20 | — | — | — | ON | — | — | — | — |
| Accept USD 20factory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| Harness Disable | — | — | — | — | — | — | ON | — |
| Harness Enablefactory default | — | — | — | — | — | — | OFF | — |
| Inhibit Active High | — | — | — | — | — | — | — | ON |
| Inhibit Active Lowfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 |
|---|---|---|
| 1 Pulse / USD 1factory default | OFF | OFF |
| 2 Pulses / USD 1 | ON | OFF |
| 4 Pulses / USD 1 | OFF | ON |
| 20 Pulses / USD 1 | ON | ON |
| Function | SW3 | SW4 |
|---|---|---|
| Pulse Speed: 50ms LO / 50ms HIfactory default | OFF | OFF |
| Pulse Speed: 60ms LO / 300ms HI | ON | OFF |
| Pulse Speed: 30ms LO / 50ms HI | OFF | ON |
| Pulse Speed: 150ms LO / 150ms HI | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| MDB Interface | — | OFF | OFF | — |
| ICT004 Interfacefactory default | — | OFF | ON | — |
| Reserved | — | ON | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal Highfactory default | ON | — | — | — |
| Credit-Pulse Normal Low | OFF | — | — | — |
| Pulse Modefactory default | — | ON | OFF | — |
| MDB Interface | — | OFF | OFF | — |
| ICT004 Interface | — | OFF | ON | — |
| Reserved | — | ON | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory default | ON | — | — | — |
| Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0 | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| MDB Interfacefactory default | — | OFF | OFF | — |
| ICT004 Interface | — | OFF | ON | — |
| Reserved | — | ON | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Bill value | ICT004 | Pulse | MDB |
|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | USD 5 | Reserved |
| BV3 | USD 10 | USD 10 | USD 5 |
| BV4 | USD 20 | USD 20 | USD 10 |
| BV5 | — | — | USD 20 |
Before you power up
- Default setting.
- Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
- Remove the front cover and the dip-switch in on the CPU board. (Please refer to “Sw1” setting.)
- Factory configuration has all switches in the OFF position.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.