Official ICT switch settings
TK77-USD4 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWZ5US420-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW9 | SW10 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 Pulse / USD 1factory default | OFF | OFF | — | — | — | — | — | — | — | — |
| 2 Pulses / USD 1 | OFF | ON | — | — | — | — | — | — | — | — |
| 4 Pulses / USD 1 | ON | OFF | — | — | — | — | — | — | — | — |
| 20 Pulses / USD 1 | ON | ON | — | — | — | — | — | — | — | — |
| Enable Fish Stopfactory default | — | — | ON | — | — | — | — | — | — | — |
| Disable Fish Stop | — | — | OFF | — | — | — | — | — | — | — |
| Inhibit level Active Low | — | — | — | ON | — | — | — | — | — | — |
| Inhibit level Active Highfactory default | — | — | — | OFF | — | — | — | — | — | — |
| Accept USD 1 & 5factory default | — | — | — | — | ON | — | — | — | — | — |
| Reject USD 1 & 5 | — | — | — | — | OFF | — | — | — | — | — |
| Accept USD 10factory default | — | — | — | — | — | ON | — | — | — | — |
| Reject USD 10 | — | — | — | — | — | OFF | — | — | — | — |
| Accept USD 20factory default | — | — | — | — | — | — | ON | — | — | — |
| Reject USD 20 | — | — | — | — | — | — | OFF | — | — | — |
| Pulse Normal Highfactory default | — | — | — | — | — | — | — | ON | — | — |
| Pulse Normal Low | — | — | — | — | — | — | — | OFF | — | — |
| Enable Output Sensor Detectfactory default | — | — | — | — | — | — | — | — | ON | — |
| Disable Output Sensor Detect | — | — | — | — | — | — | — | — | OFF | — |
| Pulse Modefactory default | — | — | — | — | — | — | — | — | — | ON |
| ICT104U Mode | — | — | — | — | — | — | — | — | — | OFF |
| Bill value | Pulse | ICT104U |
|---|---|---|
| BV1 | USD 1 | USD 1 |
| BV2 | — | — |
| BV3 | USD 5 | USD 5 |
| BV4 | USD 10 | USD 10 |
| BV5 | USD 20 | USD 20 |
Before you power up
- Please reset the bill acceptor after set the DIP switch.
- Pulse mode has out of service function.
- Out of service: Normal High, Error Low.
- Pulse speed is Lo = 50ms / Hi = 100ms.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.