Official ICT switch settings

TK77-USD4 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWZ5US420-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

TK77 DIP SWITCHES SETTING: (Pulse/Out of Service/ICT104U)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW9SW10
1 Pulse / USD 1factory defaultOFFOFF
2 Pulses / USD 1OFFON
4 Pulses / USD 1ONOFF
20 Pulses / USD 1ONON
Enable Fish Stopfactory defaultON
Disable Fish StopOFF
Inhibit level Active LowON
Inhibit level Active Highfactory defaultOFF
Accept USD 1 & 5factory defaultON
Reject USD 1 & 5OFF
Accept USD 10factory defaultON
Reject USD 10OFF
Accept USD 20factory defaultON
Reject USD 20OFF
Pulse Normal Highfactory defaultON
Pulse Normal LowOFF
Enable Output Sensor Detectfactory defaultON
Disable Output Sensor DetectOFF
Pulse Modefactory defaultON
ICT104U ModeOFF
Currency Assign Data
Bill valuePulseICT104U
BV1USD 1USD 1
BV2
BV3USD 5USD 5
BV4USD 10USD 10
BV5USD 20USD 20
Before you power up
  • Please reset the bill acceptor after set the DIP switch.
  • Pulse mode has out of service function.
  • Out of service: Normal High, Error Low.
  • Pulse speed is Lo = 50ms / Hi = 100ms.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.