Official ICT switch settings
TAO-V-AED7(AED5+USD2) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWCPAE73000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject AED 5 & 10 | ON | — | — | — | — | — | — | — |
| Accept AED 5 & 10factory default | OFF | — | — | — | — | — | — | — |
| Reject AED 20 & 50 | — | ON | — | — | — | — | — | — |
| Accept AED 20 & 50factory default | — | OFF | — | — | — | — | — | — |
| Reject AED 100 | — | — | ON | — | — | — | — | — |
| Accept AED 100factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 1 | — | — | — | ON | — | — | — | — |
| Accept USD 1factory default | — | — | — | OFF | — | — | — | — |
| Reject USD 5 | — | — | — | — | ON | — | — | — |
| Accept USD 5factory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| BA stops working when fishing | — | — | — | — | — | — | ON | — |
| Normalfactory default | — | — | — | — | — | — | OFF | — |
| Reserved | — | — | — | — | — | — | — | ON |
| Reservedfactory default | — | — | — | — | — | — | — | OFF |
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Reserved | — | ON | — | — |
| Reservedfactory default | — | OFF | — | — |
| Reserved | — | — | ON | — |
| Reservedfactory default | — | — | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory default | ON | — | — | — |
| Scaling Factor (SF) = 10; Decimal Point Position (DPP) = 1 | OFF | — | — | — |
| MDB Interfacefactory default | — | ON | — | — |
| Reserved | — | OFF | — | — |
| AED 2.5 / USD$1factory default | — | — | OFF | OFF |
| AED 3.0 / USD$1 | — | — | OFF | ON |
| AED 3.5 / USD$1 | — | — | ON | OFF |
| Reserved | — | — | ON | ON |
| Bill value | MDB |
|---|---|
| BV1 | AED 5 |
| BV2 | AED 10 |
| BV3 | AED 20 |
| BV4 | AED 50 |
| BV5 | AED 100 |
| BV6 | USD 1 |
| BV7 | USD 5 |
Before you power up
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- Note: (1) Default setting.
- (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol. USD $1 display AED 2.5 / AED 3.0 / AED 3.5. USD $5 display AED 15.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.
