Official ICT switch settings
TAO-V-MUP4(MXP2+USD2) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWH5MU42000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — |
| Reject MXP 20 | — | ON | — | — | — | — | — | — |
| Accept MXP 20factory default | — | OFF | — | — | — | — | — | — |
| Reject MXP 50 | — | — | ON | — | — | — | — | — |
| Accept MXP 50factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 5 | — | — | — | ON | — | — | — | — |
| Accept USD 5factory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| Harness Disable — BA stops working when fishing | — | — | — | — | — | — | ON | — |
| Harness Enable — Normalfactory default | — | — | — | — | — | — | OFF | — |
| Inhibit Active High | — | — | — | — | — | — | — | ON |
| Inhibit Active Lowfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 |
|---|---|---|
| 1 pulse / MXP 10 & USD 1factory default | OFF | OFF |
| 2 pulses / MXP 10 & USD 1 | ON | OFF |
| 5 pulses / MXP 10 & USD 1 | OFF | ON |
| 10 pulses / MXP 10 & USD 1 | ON | ON |
| Function | SW3 | SW4 |
|---|---|---|
| Interface Timing Conversion: 50ms LO / 50ms HIfactory default | OFF | OFF |
| Interface Timing Conversion: 60ms LO / 300ms HI | ON | OFF |
| Interface Timing Conversion: 30ms LO / 50ms HI | OFF | ON |
| Interface Timing Conversion: 150ms LO / 150ms HI | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | — | — |
| MDB Interface | — | OFF | — | — |
| Reserved | — | — | ON | — |
| Reservedfactory default | — | — | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory default | ON | — | — | — |
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2 | OFF | — | — | — |
| Pulse Mode | — | ON | — | — |
| MDB Interfacefactory default | — | OFF | — | — |
| Reserved | — | — | ON | — |
| Reservedfactory default | — | — | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Bill value | Pulse | MDB |
|---|---|---|
| BV1 | USD 1 | USD 1 |
| BV2 | MXP 20 | MXP 20 |
| BV3 | MXP 50 | MXP 50 |
| BV4 | USD 5 | USD 5 |
Before you power up
- Default setting.
- Use 2nd dip switch of the internal dip-switch to change different interface protocol.
- For Accepting US Dollars Exchange Rate on USD to MXP is 1:18 for MDB Mode.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.