TAO-A.V-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWM6US610-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

TAO-A.V Option Switch Settings: 1 (Pulse / ICT104V / ICT104U / MDB)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW1-2SW2-2SW3-2SW4-2
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
1 pulse / USD 1OFFOFF
2 pulses / USD 1ONOFF
4 pulses / USD 1factory defaultOFFON
20 pulses / USD 1ONON
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
  • The internal switch block repeats the SW1–SW4 header; -2 disambiguates it in this JSON.
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT104V InterfaceOFFON
ICT104U InterfaceOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104V Interfacefactory defaultOFFON
ICT104U InterfaceOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104V InterfaceOFFON
ICT104U Interfacefactory defaultOFFOFF
MDB InterfaceONON
ReservedON
Reservedfactory defaultOFF
TAO-V-USD6 Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT104V InterfaceOFFON
ICT104U InterfaceOFFOFF
MDB Interfacefactory defaultONON
Reservedfactory defaultON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT104UPulseMDBICT104V
BV1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5USD 5
BV3USD 10USD 10USD 10USD 10
BV4USD 20USD 20USD 20USD 20
BV5USD 50USD 50USD 50USD 50
BV6USD 100USD 100USD 100USD 100
BV7USD 100
Before you power up
  • Default setting.
  • Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • Remove the front cover and the dip-switch on the CPU board. (Please refer to “SW1” setting.)