Official ICT switch settings

TAO-V+MXN9 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWH5MX90600-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

TAO-V Option Switch Settings: 1 (Pulse/MDB) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject MXN 20 & USD 1ON
Accept MXN 20 & USD 1factory defaultOFF
Reject MXN 50 & USD 5ON
Accept MXN 50 & USD 5factory defaultOFF
Reject MXN 100 & USD 10ON
Accept MXN 100 & USD 10factory defaultOFF
Reject MXN 200 & MXN 500 & USD 20ON
Accept MXN 200 & MXN 500 & USD 20factory defaultOFF
Accept Mexico Pesos and US Dollars (Note 3)ON
Accept Mexico Pesos Only (Note 3)factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Pulse Mode / Other Mode
Harness Disable — BA stops working when fishingON
Harness Enable — Normalfactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
  • For accepting US Dollars, make sure you have dip 5 set to ON position.
  • Exchange Rate on USD to MXN is 1:15 for MDB Mode.
TAO-V Option Switch Settings: 1 (Pulse/MDB) — 4-switch pulse setting
FunctionSW1SW2SW3SW4
1 pulse / MXN 10 & USD 1factory defaultOFFOFF
2 pulses / MXN 10 & USD 1ONOFF
5 pulses / MXN 10 & USD 1OFFON
10 pulses / MXN 10 & USD 1ONON
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
MDB InterfaceOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 0OFF
Pulse ModeON
MDB Interfacefactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valuePulseMDB
BV1USD 1USD 1
BV2MXN 20MXN 20
BV3MXN 50MXN 50
BV4MXN 100MXN 100
BV5MXN 200MXN 200
BV6MXN 500MXN 500
BV7USD 5USD 5
BV8USD 10USD 10
BV9USD 20USD 20
Before you power up
  • Default setting.
  • Use the 2nd dip switch of the internal dip-switch to change different interface protocol.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp