Official ICT switch settings

TAO-A.V-MXN4(MXN2+USD2) DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWO8MX40200-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

TAO-V dip-switch settings and functions (8-switch DIP)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject N$ 20ON
Accept N$ 20factory defaultOFF
Reject N$ 50ON
Accept N$ 50factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness Disable (Other Mode: BA stops working when fishing)ON
Harness Enable (Other Mode: Normal)factory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
TAO-V dip-switch settings and functions (4-switch DIP)
FunctionSW1SW2SW3SW4
1 pulse / N$ 10 / USD $1factory defaultOFFOFF
2 pulses / N$ 10 / USD $1ONOFF
5 pulses / N$ 10 / USD $1OFFON
10 pulses / N$ 10 / USD $1ONON
Interface Timing Conversion: 50ms HI / 50ms LOfactory defaultOFFOFF
Interface Timing Conversion: 300ms HI / 60ms LOONOFF
Interface Timing Conversion: 50ms HI / 30ms LOOFFON
Interface Timing Conversion: 150ms HI / 150ms LOONON
Interface Settings: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultONOFF
ICT104U ModeOFFON
ICT104V ModeONON
MDB ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104U)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeONOFF
ICT104U Modefactory defaultOFFON
ICT104V ModeONON
MDB ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (ICT104V)
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeONOFF
ICT104U ModeOFFON
ICT104V Modefactory defaultONON
MDB ModeOFFOFF
ReservedON
Reservedfactory defaultOFF
Interface Settings: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2OFF
Pulse ModeONOFF
ICT104U ModeOFFON
ICT104V ModeONON
MDB Modefactory defaultOFFOFF
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueICT104UPulseMDBICT104V
BV1USD $1USD $1USD $1USD $1
BV2N$ 20N$ 20N$ 20N$ 20
BV3N$ 50N$ 50N$ 50N$ 50
BV4USD $5USD $5USD $5USD $5
Before you power up
  • Default setting.
  • Use 2nd dip switch of the internal dip-switch to change different interface protocol.
  • For Accepting US Dollars, make sure you have dip 5 set to ON position. (Exchange Rate on USD to MXP is 1:15 for MDB Mode)

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp