Official ICT switch settings
TAO-A.V-MXN4(MXN2+USD2) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWO8MX40200-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject USD 1 | ON | — | — | — | — | — | — | — |
| Accept USD 1factory default | OFF | — | — | — | — | — | — | — |
| Reject N$ 20 | — | ON | — | — | — | — | — | — |
| Accept N$ 20factory default | — | OFF | — | — | — | — | — | — |
| Reject N$ 50 | — | — | ON | — | — | — | — | — |
| Accept N$ 50factory default | — | — | OFF | — | — | — | — | — |
| Reject USD 5 | — | — | — | ON | — | — | — | — |
| Accept USD 5factory default | — | — | — | OFF | — | — | — | — |
| Reserved | — | — | — | — | ON | — | — | — |
| Reservedfactory default | — | — | — | — | OFF | — | — | — |
| Reserved | — | — | — | — | — | ON | — | — |
| Reservedfactory default | — | — | — | — | — | OFF | — | — |
| Harness Disable (Other Mode: BA stops working when fishing) | — | — | — | — | — | — | ON | — |
| Harness Enable (Other Mode: Normal)factory default | — | — | — | — | — | — | OFF | — |
| Inhibit Active High | — | — | — | — | — | — | — | ON |
| Inhibit Active Lowfactory default | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| 1 pulse / N$ 10 / USD $1factory default | OFF | OFF | — | — |
| 2 pulses / N$ 10 / USD $1 | ON | OFF | — | — |
| 5 pulses / N$ 10 / USD $1 | OFF | ON | — | — |
| 10 pulses / N$ 10 / USD $1 | ON | ON | — | — |
| Interface Timing Conversion: 50ms HI / 50ms LOfactory default | — | — | OFF | OFF |
| Interface Timing Conversion: 300ms HI / 60ms LO | — | — | ON | OFF |
| Interface Timing Conversion: 50ms HI / 30ms LO | — | — | OFF | ON |
| Interface Timing Conversion: 150ms HI / 150ms LO | — | — | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | OFF | — |
| ICT104U Mode | — | OFF | ON | — |
| ICT104V Mode | — | ON | ON | — |
| MDB Mode | — | OFF | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| ICT104U Modefactory default | — | OFF | ON | — |
| ICT104V Mode | — | ON | ON | — |
| MDB Mode | — | OFF | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| ICT104U Mode | — | OFF | ON | — |
| ICT104V Modefactory default | — | ON | ON | — |
| MDB Mode | — | OFF | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory default | ON | — | — | — |
| Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2 | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| ICT104U Mode | — | OFF | ON | — |
| ICT104V Mode | — | ON | ON | — |
| MDB Modefactory default | — | OFF | OFF | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Bill value | ICT104U | Pulse | MDB | ICT104V |
|---|---|---|---|---|
| BV1 | USD $1 | USD $1 | USD $1 | USD $1 |
| BV2 | N$ 20 | N$ 20 | N$ 20 | N$ 20 |
| BV3 | N$ 50 | N$ 50 | N$ 50 | N$ 50 |
| BV4 | USD $5 | USD $5 | USD $5 | USD $5 |
Before you power up
- Default setting.
- Use 2nd dip switch of the internal dip-switch to change different interface protocol.
- For Accepting US Dollars, make sure you have dip 5 set to ON position. (Exchange Rate on USD to MXP is 1:15 for MDB Mode)
Not the sheet for your unit?