Official ICT switch settings

S7ER-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWP4US61001-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

S7ER Option Switch Settings (Pulse): primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Stack Banknote when Power-upON
Reject Banknote when Power-upfactory defaultOFF
Inhibit Active HIGHON
Inhibit Active LOWfactory defaultOFF
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: 1. No RFID function.
S7ER Option Switch Settings (Pulse): auxiliary settings 1
FunctionSW1SW2SW3SW4
Pulse Speed: 100ms LO / 100ms HION
Pulse Speed: 50ms LO / 50ms HIfactory defaultOFF
ReserveON
Reservefactory defaultOFF
ReserveON
Reservefactory defaultOFF
ReserveON
Reservefactory defaultOFF
S7ER Option Switch Settings (Pulse): auxiliary settings 2
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
ICT104U ModeOFF
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1OFFON
4 pulses / USD 1ONOFF
20 pulses / USD 1ONON
S7ER-USD6 (ICT104U): primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ON
Accept USD 1factory defaultOFF
Reject USD 5ON
Accept USD 5factory defaultOFF
Reject USD 10ON
Accept USD 10factory defaultOFF
Reject USD 20ON
Accept USD 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Stack Banknote when Power-upON
Reject Banknote when Power-upfactory defaultOFF
Test Mode (No Communication)ON
Operation Modefactory defaultOFF
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: 1. No RFID function.
S7ER-USD6 (ICT104U): auxiliary settings 1
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
S7ER-USD6 (ICT104U): auxiliary settings 2
FunctionSW1SW2SW3SW4
ReservedON
Reservedfactory defaultOFF
Pulse ModeON
ICT104U Modefactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valuePulseICT1040
BV1USD 1USD 1
BV2USD 5USD 5
BV3USD 10USD 10
BV4USD 20USD 20
BV5USD 50USD 50
BV6USD 100USD 100
Before you power up
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: 1. No RFID function.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp