Official ICT switch settings

S7A II-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWQ8US60400-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

S7A II-USD6 Option Switch Settings (Pulse / MDB / ICT104U / Parallel A3)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW1-2SW2-2SW3-2SW4-2
Reject USD 1 & 5ON
Accept USD 1 & 5factory defaultOFF
Reject USD 10 & 20ON
Accept USD 10 & 20factory defaultOFF
Reject USD 50 & 100ON
Accept USD 50 & 100factory defaultOFF
High AcceptanceON
High Securityfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Disable Bill Reject 4 Times; BA Stop By 30 SecON
Enable Bill Reject 4 Times; BA Stop By 30 Secfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Other Interface — Test Mode (No Communication)ON
Other Interface — Operation Modefactory defaultOFF
Pulse Mode — Inhibit Active HIGH (Test)factory defaultON
Pulse Mode — Inhibit Active LOWfactory defaultOFF
ENABLE IrDA DownloadON
Reservedfactory defaultOFF
ENABLE INHIBIT-Sleep OnlyON
5 second Timeout Onlyfactory defaultOFF
NORMALOFFOFF
MODE1OFFON
MODE2ONOFF
MODE1+2factory defaultONON
  • The second switch block repeats the SW1–SW4 header; -2 disambiguates it in this JSON.
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse Modefactory defaultON
Other ModeOFF
1 pulse / USD 1factory defaultOFFOFF
2 pulses / USD 1OFFON
4 pulses / USD 1ONOFF
20 pulses / USD 1ONON
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeON
Other Modefactory defaultOFF
MDBOFFOFF
ICT104Ufactory defaultOFFON
ReservedONON
Parallel A3ONOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeON
Other Modefactory defaultOFF
MDBfactory defaultOFFOFF
ICT104UOFFON
ReservedONON
Parallel A3ONOFF
DIP SWITCHES SETTING: 2 (Parallel A3)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeON
Other Modefactory defaultOFF
MDBOFFOFF
ICT104UOFFON
ReservedONON
Parallel A3factory defaultONOFF
Currency Assign Data
Bill valuePulseMDBICT104UParallel A3
BV1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5USD 5
BV3USD 10USD 10USD 10USD 10
BV4USD 20USD 20USD 20USD 20
BV5USD 50USD 50USD 50USD 50
BV6USD 100USD 100USD 100USD 100
Before you power up
  • After setting the dip switch of the credit pulses, you should reset the bill acceptor again.
  • NORMAL: No sleep function.
  • MODE 1: Bill-acceptor wakes up VMC with banknote only (special cable required).
  • MODE 2: VMC wakes up bill-acceptor.
  • MODE 1+2: Bill-acceptor wakes up with banknote or by VMC.