DIP SWITCHES SETTING: (Parallel A4)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW9SW10
With Escow FunctionON
No Escow Functionfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Enable Output Sensor Detect (★★)factory defaultON
Disable Output Sensor Detect (★★)OFF
ReservedON
Reservedfactory defaultOFF
Optical anti-fishing malfunction, BA will be still in working order (★★★)ON
BA will stop to work when it acknowledges Optical anti-fishing malfunction (★★★)factory defaultOFF
Accept USD $1 & 5 & 10 & 20factory defaultON
Reject USD $1 & 5 & 10 & 20OFF
Accept USD $50 & 100factory defaultON
Reject USD $50 & 100OFF
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Pulse ProtocolON
Parallel A4 Protocolfactory defaultOFF
DIP SWITCHES SETTING: (Pulse)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW9SW10
5 Pulses / USD $1ON
1 Pulse / USD $1factory defaultOFF
Lo = 150ms / Hi = 180msfactory defaultOFFOFF
Lo = 50ms / Hi = 50msOFFON
Lo = 80ms / Hi = 120msONOFF
Lo = 50ms / Hi = 300msONON
Enable Output Sensor Detect (★★)factory defaultON
Disable Output Sensor Detect (★★)OFF
Inhibit level Active HighON
Inhibit level Active Lowfactory defaultOFF
Optical anti-fishing malfunction, BA will be still in working order (★★★)ON
BA will stop to work when it acknowledges Optical anti-fishing malfunction (★★★)factory defaultOFF
Accept USD $1 & 5 & 10 & 20factory defaultON
Reject USD $1 & 5 & 10 & 20OFF
Accept USD $50 & 100factory defaultON
Reject USD $50 & 100OFF
Disable Bill Reject 4 Times BA Stop By 30 SecON
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultOFF
Pulse Protocolfactory defaultON
Parallel A4 ProtocolOFF
Currency Assign Data
Bill valuePulseParallel A4
BV1USD 1USD 1
BV2USD 5USD 5
BV3USD 10USD 10
BV4USD 20USD 20
BV5USD 50USD 50
BV6USD 100USD 100
Before you power up
  • ★★ ON: Autocheck motor reversal. OFF: When output or hook is triggered in power on, error message displays three red, until after trouble clearing into autocheck.
  • ★★★ ON: (1) After accepted banknotes through output sensor, if detect output trigger again, display sensor problem. (2) After accepted banknote didn’t leave output sensor, display sensor problem. OFF: (1) After accepted banknotes through output sensor, if detect output trigger again, display sensor problem. (2) After accepted banknote didn’t leave output sensor, return to the idle.
  • Please restart the bill acceptor after any changes on dip switch(s) has been made.