NBA-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWCJUS6300-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

NBA DIP SWITCH SETTINGS: 1 (Pulse / RS232 A0 / ICT104U / RS232 A1 / EBDS)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Accept US$ 1factory defaultON
Reject US$ 1OFF
Accept US$ 5factory defaultON
Reject US$ 5OFF
Accept US$ 10factory defaultON
Reject US$ 10OFF
Accept US$ 20factory defaultON
Reject US$ 20OFF
Accept US$ 50factory defaultON
Reject US$ 50OFF
Accept US$ 100factory defaultON
Reject US$ 100OFF
Harness Enablefactory defaultON
Harness DisableOFF
Inhibit Active Highfactory defaultON
Inhibit Active LowOFF
DIP SWITCHES SETTING: 2
FunctionSW1SW2SW3SW4SW1-2SW2-2SW3-2SW4-2
1 pulse / US$ 1factory defaultOFFOFF
2 pulses / US$ 1ONOFF
4 pulses / US$ 1OFFON
10 pulses / US$ 1ONON
Pulse Speed: 50ms LO / 50ms HIfactory defaultOFFOFF
Pulse Speed: 30ms LO / 50ms HIONOFF
Pulse Speed: 60ms LO / 300ms HIOFFON
Pulse Speed: 150ms LO / 150ms HIONON
EBDS Modefactory defaultOFFOFF
ICT104U ModeONOFF
RS232 A1 ModeOFFON
RS232 A0 ModeONON
ON
OFF
ON
OFF
  • The second switch block is printed with a repeated SW1–SW4 header; -2 disambiguates it in this JSON.
DIP SWITCHES SETTING: 3
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
Others Mode (Note 2)OFF
RFID function Enablefactory defaultON
RFID function DisableOFF
Optical anti-fishing malfunction, BA will be still in working orderON
BA will stop work when it acknowledges optical anti-fishing malfunction.factory defaultOFF
Currency Assign Data
Bill valuePulseRS232 A0ICT104URS232 A1EBDS
BV1US$ 1US$ 1US$ 1US$ 1US$ 1
BV2US$ 5US$ 5US$ 5
BV3US$ 10US$ 5US$ 10US$ 5US$ 5
BV4US$ 20US$ 10US$ 20US$ 10US$ 10
BV5US$ 50US$ 20US$ 50US$ 20US$ 20
BV6US$ 100US$ 50US$ 100US$ 50US$ 50
BV7US$ 100US$ 100
Before you power up
  • Please reset the bill acceptor after any changes on DIP switch.
  • SW2 (front panel right block) Dip Switch 1 to 4 are only for Pulse mode. If set to others mode, SW2 Dip Switch 1 to 4 can change to different interface.
  • Barcode reader calibration procedure: Turn all bill values under reject mode; restart power; insert blank barcode ticket to calibrate reader head and NBA bezel flashing in green for 2 seconds; restore the original dip switch setting and restart power.