Official ICT switch settings
NBA-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWMOU56051-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Accept US$ 1factory default | ON | — | — | — | — | — | — | — |
| Reject US$ 1 | OFF | — | — | — | — | — | — | — |
| Accept US$ 5factory default | — | ON | — | — | — | — | — | — |
| Reject US$ 5 | — | OFF | — | — | — | — | — | — |
| Accept US$ 10factory default | — | — | ON | — | — | — | — | — |
| Reject US$ 10 | — | — | OFF | — | — | — | — | — |
| Accept US$ 20factory default | — | — | — | ON | — | — | — | — |
| Reject US$ 20 | — | — | — | OFF | — | — | — | — |
| Accept US$ 50factory default | — | — | — | — | ON | — | — | — |
| Reject US$ 50 | — | — | — | — | OFF | — | — | — |
| Accept US$ 100factory default | — | — | — | — | — | ON | — | — |
| Reject US$ 100 | — | — | — | — | — | OFF | — | — |
| Harness Enablefactory default | — | — | — | — | — | — | ON | — |
| Harness Disable | — | — | — | — | — | — | OFF | — |
| Inhibit Active High — CRC 16-bit checksum (ccTalk only)factory default | — | — | — | — | — | — | — | ON |
| Inhibit Active Low — 8-bit checksum (ccTalk only) | — | — | — | — | — | — | — | OFF |
- Triangle-marked rows are for pulse interface only.
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| 1 pulse / US$ 1factory default | OFF | OFF | — | — |
| 2 pulses / US$ 1 | ON | OFF | — | — |
| 4 pulses / US$ 1 | OFF | ON | — | — |
| 10 pulses / US$ 1 | ON | ON | — | — |
| Pulse Speed: 50ms LO / 50ms HIfactory default | — | — | OFF | OFF |
| Pulse Speed: 30ms LO / 50ms HI | — | — | ON | OFF |
| Pulse Speed: 60ms LO / 300ms HI | — | — | OFF | ON |
| Pulse Speed: 150ms LO / 150ms HI | — | — | ON | ON |
- Triangle-marked rows are for pulse interface only.
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| ccTalk Modefactory default | OFF | OFF | — | — |
| ICT002U Mode | ON | OFF | — | — |
| RS232 A1 Mode | OFF | ON | — | — |
| RS232 A0 Mode | ON | ON | — | — |
| ccTalk Parameters Restore Switch (Please see Note 3 for detail) | — | — | ON | — |
| ccTalk Interfacefactory default | — | — | OFF | — |
| Encryption Mode (for ccTalk Mode use only)factory default | — | — | — | ON |
| Decrypt Mode | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | — | — | — |
| Credit-Pulse Normal LOW | OFF | — | — | — |
| Pulse Modefactory default | — | ON | — | — |
| Others Mode (Note 2) | — | OFF | — | — |
| RFID and Barcode function Enablefactory default | — | — | ON | — |
| RFID and Barcode function Disable | — | — | OFF | — |
| Optical anti-fishing malfunction, BA will be still in working orderfactory default | — | — | — | ON |
| BA will stop work when it acknowledges optical anti-fishing malfunction. | — | — | — | OFF |
- Triangle-marked rows are for pulse interface only.
| Function |
|---|
| Code 1 — US$ 1 |
| Code 2 — Reserved |
| Code 3 — US$ 5 |
| Code 4 — US$ 10 |
| Code 5 — US$ 20 |
| Code 6 — US$ 50 |
| Code 7 — US$ 100 |
| Code 8 — Reserved |
| Bill value | Pulse | RS232 A0 | ICT002U | RS232 A1 | ccTalk |
|---|---|---|---|---|---|
| BV1 | US$ 1 | US$ 1 | US$ 1 | US$ 1 | US$ 1 |
| BV2 | US$ 5 | US$ 5 | US$ 5 | US$ 5 | US$ 5 |
| BV3 | US$ 10 | US$ 10 | US$ 10 | US$ 10 | US$ 10 |
| BV4 | US$ 20 | US$ 20 | US$ 20 | US$ 20 | US$ 20 |
| BV5 | US$ 50 | US$ 50 | US$ 50 | US$ 50 | US$ 50 |
| BV6 | US$ 100 | US$ 100 | US$ 100 | US$ 100 | US$ 100 |
Before you power up
- Please reset the bill acceptor after any changes on Dip switch.
- SW2 (front panel right block) Dip Switch 1 to 4 are only for Pulse mode.
- If set to others mode, SW2 Dip Switch 1 to 4 can change to different interface setting.
- Turn this dip switch to first and the bill acceptor will restore ccTalk address to its default value of 40 and the encryption key to its default value of 123456.
- Barcode reader calibration procedure: 1. Turn all bill values under reject mode. 2. Restart power. 3. Insert the blank barcode ticket to calibrate the reader head, and NBA’s bezel flashing in green for 2 seconds. 4. Restore the original dip switch setting and restart the power.
- RS232 Automation.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.