Official ICT switch settings
PL77/L77F-UCD9(USD6+CAD3) DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWY6UC910-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW9 | SW10 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 Pulse / USD 1factory default | OFF | OFF | OFF | — | — | — | — | — | — | — |
| 2 Pulse / USD 1 | OFF | OFF | ON | — | — | — | — | — | — | — |
| 3 Pulse / USD 1 | OFF | ON | OFF | — | — | — | — | — | — | — |
| 4 Pulse / USD 1 | OFF | ON | ON | — | — | — | — | — | — | — |
| 5 Pulse / USD 1 | ON | OFF | OFF | — | — | — | — | — | — | — |
| 10 Pulse / USD 1 | ON | OFF | ON | — | — | — | — | — | — | — |
| 20 Pulse / USD 1 | ON | ON | OFF | — | — | — | — | — | — | — |
| 100 Pulse / USD 1 | ON | ON | ON | — | — | — | — | — | — | — |
| Fast output Pulse (Lo = 50ms, Hi = 100ms) | — | — | — | ON | — | — | — | — | — | — |
| Slow output Pulse (Lo = 50ms, Hi = 300ms)factory default | — | — | — | OFF | — | — | — | — | — | — |
| Inhibit level Active Low | — | — | — | — | ON | — | — | — | — | — |
| Inhibit level Active Highfactory default | — | — | — | — | OFF | — | — | — | — | — |
| Accept USD 1 & 5factory default | — | — | — | — | — | ON | — | — | — | — |
| Reject USD 1 & 5 | — | — | — | — | — | OFF | — | — | — | — |
| Accept USD 10 & 20factory default | — | — | — | — | — | — | ON | — | — | — |
| Reject USD 10 & 20 | — | — | — | — | — | — | OFF | — | — | — |
| Accept USD 50 & 100 | — | — | — | — | — | — | — | ON | — | — |
| Reject USD 50 & 100factory default | — | — | — | — | — | — | — | OFF | — | — |
| Accept CAD 5 & 10 & 20factory default | — | — | — | — | — | — | — | — | ON | — |
| Reject CAD 5 & 10 & 20 | — | — | — | — | — | — | — | — | OFF | — |
| Accept USD + CADfactory default | — | — | — | — | — | — | — | — | — | ON |
| Accept only CAD | — | — | — | — | — | — | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal Highfactory default | ON | — | — | — |
| Credit-Pulse Normal Low | OFF | — | — | — |
| Pulse Modefactory default | — | ON | OFF | — |
| ccTalk Interface | — | OFF | OFF | — |
| ICT104U Mode | — | ON | ON | — |
| Reserved | — | OFF | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| 8-bit checksum | ON | — | — | — |
| CRC 16-bit checksumfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| ccTalk Interfacefactory default | — | OFF | OFF | — |
| ICT104U Mode | — | ON | ON | — |
| ccTalk Parameters Restore Switch — Please see "Note" for detail | — | OFF | ON | — |
| Encryption Modefactory default | — | — | — | ON |
| Decrypt Mode | — | — | — | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | — | — | — |
| Reservedfactory default | OFF | — | — | — |
| Pulse Mode | — | ON | OFF | — |
| ccTalk Interface | — | OFF | OFF | — |
| ICT104U Modefactory default | — | ON | ON | — |
| Reserved | — | OFF | ON | — |
| Reserved | — | — | — | ON |
| Reservedfactory default | — | — | — | OFF |
| Bill value | Pulse | ICT104U | ccTalk |
|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | USD 5 | USD 5 |
| BV3 | USD 10 | USD 10 | USD 10 |
| BV4 | USD 20 | USD 20 | USD 20 |
| BV5 | USD 50 | USD 50 | USD 50 |
| BV6 | USD 100 | USD 100 | USD 100 |
| BV7 | CAD 5 | CAD 5 | CAD 5 |
| BV8 | CAD 10 | CAD 10 | CAD 10 |
| BV9 | CAD 20 | CAD 20 | CAD 20 |
Before you power up
- (1) Please reset the bill acceptor after any changes on Dip switch.
- (2) Dip Switch 1 to 5 are only for Pulse mode.
- (3) Turn this dip to with restart the bill acceptor will restore ccTalk address to its default value of 40 and the encryption key to its default value of 123456.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.