Official ICT switch settings

L70+/L70F-USD6 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWM8US630-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

L70+/L70F/P5 DIP SWITCHES SETTING: 1 (Pulse/ICT104U/ICT104V/MDB)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8SW9SW10
1 Pulse / USD 1factory defaultOFFOFFOFF
2 Pulse / USD 1OFFOFFON
3 Pulse / USD 1OFFONOFF
4 Pulse / USD 1OFFONON
5 Pulse / USD 1ONOFFOFF
10 Pulse / USD 1ONOFFON
20 Pulse / USD 1ONONOFF
100 Pulse / USD 1ONONON
Fast output Pulse (Lo = 50ms, Hi = 100ms)ON
Slow output Pulse (Lo = 50ms, Hi = 300ms)factory defaultOFF
Inhibit level Active LowON
Inhibit level Active Highfactory defaultOFF
Accept USD 1factory defaultON
Reject USD 1OFF
Accept USD 5factory defaultON
Reject USD 5OFF
Accept USD 10factory defaultON
Reject USD 10OFF
Accept USD 20factory defaultON
Reject USD 20OFF
Accept USD 50 & 100factory defaultON
Reject USD 50 & 100OFF
  • Dip switches 1 to 5 are only used for pulse protocol.
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Pulse Normal Highfactory defaultON
Pulse Normal LowOFF
Pulse Modefactory defaultONOFF
ICT104U ModeOFFON
MDB ModeONON
ICT104V ModeOFFOFF
Disable Inverse ModeON
Enable Inverse Modefactory defaultOFF
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104U Modefactory defaultOFFON
MDB ModeONON
ICT104V ModeOFFOFF
Disable Inverse ModeON
Enable Inverse Modefactory defaultOFF
DIP SWITCHES SETTING: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Reservedfactory defaultON
ReservedOFF
Pulse ModeONOFF
ICT104U ModeOFFON
MDB ModeONON
ICT104V Modefactory defaultOFFOFF
Disable Inverse ModeON
Enable Inverse Modefactory defaultOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Pulse ModeONOFF
ICT104U ModeOFFON
MDB Modefactory defaultONON
ICT104V ModeOFFOFF
Disable Inverse ModeON
Enable Inverse Modefactory defaultOFF
Currency Assign Data
Bill valuePulseMDBICT104UICT104V
BV1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5USD 5
BV3USD 10USD 5USD 10USD 10
BV4USD 20USD 10USD 20USD 20
BV5USD 50USD 20USD 50USD 50
BV6USD 100USD 50USD 100USD 100
BV7USD 100