Official ICT switch settings
BR2300-USD7 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWBNUS720-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW9 | SW10 |
|---|---|---|---|---|---|---|---|---|---|---|
| Reject USD 1 & 2 & 5 | ON | — | — | — | — | — | — | — | — | — |
| Accept USD 1 & 2 & 5factory default | OFF | — | — | — | — | — | — | — | — | — |
| Reject USD 10 & 20 | — | ON | — | — | — | — | — | — | — | — |
| Accept USD 10 & 20factory default | — | OFF | — | — | — | — | — | — | — | — |
| Reject USD 50 & 100 | — | — | ON | — | — | — | — | — | — | — |
| Accept USD 50 & 100factory default | — | — | OFF | — | — | — | — | — | — | — |
| High Acceptance (Note 4) | — | — | — | ON | — | — | — | — | — | — |
| High Securityfactory default | — | — | — | OFF | — | — | — | — | — | — |
| Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2 (MDB only)factory default | — | — | — | — | ON | — | — | — | — | — |
| Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0 | — | — | — | — | OFF | — | — | — | — | — |
| Normalfactory default | — | — | — | — | — | OFF | OFF | — | — | — |
| Load Banknote to Recycle | — | — | — | — | — | ON | OFF | — | — | — |
| Load Banknote to Stacker | — | — | — | — | — | OFF | ON | — | — | — |
| Unload Banknote to Stacker | — | — | — | — | — | ON | ON | — | — | — |
| ccTalkfactory default | — | — | — | — | — | — | — | ON | OFF | — |
| ccTalk (Note 1) | — | — | — | — | — | — | — | OFF | ON | — |
| MDB Modefactory default | — | — | — | — | — | — | — | OFF | OFF | — |
| ICT-BC Modefactory default | — | — | — | — | — | — | — | ON | ON | — |
| Encryption MODE — ccTalk: Virtual MDB Recycler Function; MDB Mode: Connect with MDB Connector; ICT-BC Mode: Connect with MDB Connectorfactory default | — | — | — | — | — | — | — | — | — | ON |
| Decrypt MODE — ccTalk: Standard MDB Recycler Function; MDB Mode: Connect with RS232 Connector; ICT-BC Mode: Connect with RS232 Connector | — | — | — | — | — | — | — | — | — | OFF |
- Note 1: Turn this dip to with restart the bill acceptor will restore ccTalk address to its default value of 40 and the encryption key into its default value of 123456.
- Note 2: Recycled Banknote represents virtual MDB coin type.
- Note 3: A calibration card is needed.
- Note 4: High acceptance mode will increasing accepting rate, however, it will reduce the security level of Bill Acceptor.
| Bill value | MDB | ICT-BC | ccTalk | Recycler banknote inventory |
|---|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 | 40 pcs |
| BV2 | USD 2 | USD 2 | USD 2 | 40 pcs |
| BV3 | USD 5 | USD 5 | USD 5 | 40 pcs |
| BV4 | USD 10 | USD 10 | USD 10 | 40 pcs |
| BV5 | USD 20 | USD 20 | USD 20 | 40 pcs |
| BV6 | USD 50 | USD 50 | USD 50 | 40 pcs |
| BV7 | USD 100 | USD 100 | USD 100 | 40 pcs |
Before you power up
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.