Official ICT switch settings

A6/V6-MUP8 DIP switch settings

Every switch function from ICT’s own setting sheet (part number SWAMU840-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

A6/V6 dip-switch settings and functions (8-switch DIP)
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject MXP 20 & USD 1ON
Accept MXP 20 & USD 1factory defaultOFF
Reject MXP 50 & USD 5ON
Accept MXP 50 & USD 5factory defaultOFF
Reject MXP 100 & USD 10ON
Accept MXP 100 & USD 10factory defaultOFF
Reject MXP 200 & USD 20ON
Accept MXP 200 & USD 20factory defaultOFF
Accept Mexico Pesos and US Dollars (Note 1)ON
Accept Mexico Pesos Only (Note 1)factory defaultOFF
ReservedON
Reservedfactory defaultOFF
Harness DisableON
Harness Enablefactory defaultOFF
Inhibit Active HighON
Inhibit Active Lowfactory defaultOFF
A6/V6 dip-switch settings and functions (4-switch DIP)
FunctionSW1SW2SW3SW4
1 pulse / MXP 10factory defaultOFFOFF
2 pulse / MXP 10ONOFF
5 pulse / MXP 10OFFON
10 pulse / MXP 10ONON
Interface Timing Conversion: 50ms on / 50ms offfactory defaultOFFOFF
Interface Timing Conversion: 60ms on / 300ms offONOFF
Interface Timing Conversion: 30ms on / 50ms offOFFON
Interface Timing Conversion: 150ms on / 150ms offONON
A6 Interface Settings: 2 (Pulse/RS232)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
RS232 InterfaceOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
V6 Interface Settings: 2 (M.D.B)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0OFF
ReservedON
M.D.B Interfacefactory defaultOFF
ReservedON
Reservedfactory defaultOFF
ReservedON
Reservedfactory defaultOFF
Currency Assign Data
Bill valueMDB (MXP)MDB (USD)
BV1USD 1
BV2MXP 20
BV3MXP 50USD 5
BV4MXP 100USD 10
BV5MXP 200USD 20
Before you power up
  • Factory configuration has all switches in the OFF position.
  • For Accepting US Dollars, make sure you have dip 5 set to ON position. (Exchange rate on USD to MXP is 1:10)
  • Reset the bill acceptor after setting the dip switch.
  • SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.

Call for pricing WhatsApp